- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- It is necessary to use a minimum of one flanged pulley to prevent the belt from riding off
- When the drive is operated on other than horizontal shafts, or when the center distance is greater than eight times the diameter of the smaller pulley on drive ratios less than 3:1, both pulleys should be flanged
- When a drive has three pulleys, at least two should be flanged
- If the drive has more than three pulleys, every other pulley should be flanged
| Pressure [Max] | 5000 psi |
| Operation | Pilot Operated |
| Valve Type | Standard-Duty |
| Design No. | 10 |
| Pressure Port Check Valve Code | None |
| Performance | High Performance |
| Model No. | DG5V-8-H-6C-M-FW-B-10 |
| Spool Code | 6 |
| Fluid Cleanliness | 19/17/14 micron |
| Pilot/Drain | External Pilot/Internal Drain |
| Actuator Type | Solenoid |
| Pilot Drain Code | None |
| EN Code | None |
| Housing Code | W |
| Compatible Fluids | Petroleum Oil |
| Solenoid Indicator Lights Code | None |
| Gauge Ports Code | None |
| Overrides | Plain Override Solenoid Ends |
| Coil Type Code | F |
| Solenoid | Double |
| Mechanical Options | None |
| Port T Pressure Rating | 5000 psi |
| Indicator Lights | No |
| Electrical Options Code | None |
| Seal Material | Buna-N |
| Center Position | P Blocked, A & B to T |
| Electrical Connection | No Connector |
| Port Restrictor Plugs | None |
| Mechanical Options Code | None |
| Spool Indicator Switch Code | None |
| Response Type Code | None |
| Function | 3-Position Spring Centered |
| NFPA Size | D08 |
| Gauge Port | SAE-4 |
| Surge Suppressor/Damper | None |
| Pilot Valve Type Code | H |
| Rated Flow [Max] | 175 gal/min |
| Spool Control Modification Code | None |
| Manual Override | Plain Override |
| Leakage | Standard Performance |
| Manual Override Option Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Solenoid Energization Code | None |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Reducer Module Code | None |
| Pressure Port Check Valve Pressure | N/A |
| Spool Center Condition | A Port and Double Offset sensing switch on B Port |
| Crossover | P Blocked, A or B to T |
| Pilot Pressure Code | None |
| Port Restrictor Plug Code | None |
| No. of Stages | Two Stage |
| AC/DC | AC |
| Electrical Options | None |
| Spool Spring Arrangement Code | C |
| Reducer Module | No |
| Pilot Valve Type | CETOP 3, High Performance |
| Electrical Connector Code | None |
| Response Type | Standard Response |
| Tank Port Rating | 5000 |
| Coil Rating Code | B |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| Surge Suppressor/Damper Code | None |
| Body Material | Gray Iron |
| Mounting | Subplate/Manifold Mount |
| Weight | 35.0 LB |