Vickers D03 Solenoid Valve

02-145162

Vickers D03 Solenoid Valve
Item #101856114
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function
Vickers D03 Solenoid Valve
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Solenoid Operated Operation
  • D03 NFPA Size
  • Double Solenoid
  • 3-Position, 4-Way, Spring Centered Function

description

  • Industry-standard solenoid valves provide precision directional control for any hydraulic system and can be subplate or manifold mounted.

compliances

  • 0
Model No. DG4V-3-8C-VM-U-H7-61
Port T Code 7
No. of Stages Single Stage
Surge Suppressor/Damper None
Compatible Fluids Phosphate Ester Fluids
Pressure [Max] 5000 psi
AC/DC DC
Pilot Valve Type N/A
Coil Type Code U
Fluid Cleanliness 19/17/14 micron
Port Restrictor Plug Code None
Surge Suppressor/Damper Code None
Leakage Standard Performance
Housing Code None
Spool Spring Arrangement Code C
Voltage & Frequency 24 VDC
Watt Rating 30 W
Rated Flow 10.6 gal/min
Manual Override Plain Override
Electrical Connection DIN 43650
Port Restrictor Plugs None
Temperature Range [Max] 158 °F
Port T Pressure Rating 3000 psi
Response Type Standard Response
Operation Solenoid Operated
Pilot/Drain None
Electrical Options None
Valve Type High-Performance
Body Material Gray Iron
Spool Shift Timing N/A
Coil Type ISO 4400 (Din 43650) Connector
Cycle Rate [Max] N/A
Solenoid Code H
Seal Material Viton
EN Code None
Spool Indicator Switch Code None
Rated Flow [Max] 20 gal/min
Center Position P to T, A & B Blocked
Crossover All Ports Open, Restricted
Tank Port Rating 3000
Actuator Type Solenoid
Spool Center Condition A Port and Double Offset sensing switch on B Port
Solenoid Double
Function Code 8
Reducer Module No
Solenoid Indicator Lights Code None
Coil Rating Code H
Mechanical Options None
Electrical Connector Code None
Manual Override Option Code None
Indicator Lights No
Mounting Subplate/Manifold Mount
Manufacturer Part No. DG4V 3 8C V M U H7 61
Solenoid Energization Code V
Spool Code 8
NFPA Size D03
Overrides No Overrides
Design No. 61
Function 3-Position, 4-Way, Spring Centered
Performance Standard Performance
Pressure Port Check Valve Pressure N/A
Temperature Range [Min] -4 °F
Weight 4.6 LB