Electric immersion heaters specifically designed with low watt densities for direct immersion in hydraulic and lube systems. Heavy-duty terminal enclosures available to protect integral thermostats and electrical connections from outdoor and/or hazardous locations.
applications
Custom machinery
Fluids needing low watt density
Fluid power
Compressors
Turbines and bearings
Hydraulics
features
Heaters are designed for horizontal mounting approximately 3" to 6" from the bottom of the tank so that the heating elements are totally immersed at all times
Custom heaters available designed to user's specific requirement
caution
Design allows for possible axial shifting of components relative to the shaft, so utilize this device where exact positioning is not critical
kW [Max]
1 w
Temperature Range [Min]
60 °F
Phase
Three Phase
Connection Type
2 in NPT
Immersed Length
18 in
Terminal Enclosure
Weather-Resistant
Length
24 1/2 in
Dia.
5.75 in
Temperature Range [Max]
250 °F
Voltage Rating
208 VAC 3-Phase
Weight
16.0 LB
We're here for you
with Service Centers across the country - We have your back