02-329127

Vickers D08 Solenoid Valve
Item #101979713
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-329127
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • When a drive has three pulleys, at least two should be flanged
  • If the drive has more than three pulleys, every other pulley should be flanged
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Solenoid Indicator Lights Code None
Function 3-Position Spring Centered
Coil Type ISO 4400 (Din 43650) Connector
Electrical Connector Code None
Compatible Fluids Petroleum Oil
Model No. DG5V-8-S-2C-M-U-B-10
Pilot Valve Type Code S
Tank Port Rating 5000
Port Restrictor Plug Code None
NFPA Size D08
Electrical Options None
Pressure [Max] 5000 psi
Crossover All Ports Blocked
Mechanical Options Code None
Surge Suppressor/Damper Code None
Spool Control Modification Code None
Surge Suppressor/Damper None
Pressure Port Check Valve Code None
Port Restrictor Plugs None
Spool Code 2
Overrides Plain Override Solenoid Ends
Center Position All Ports Blocked
Gauge Ports Code None
Indicator Lights No
Port T Pressure Rating 5000 psi
Gauge Port SAE-4
Response Type Standard Response
EN Code None
Electrical Connection No Connector
Pilot Valve Type CETOP 3, Standard Performance
Voltage & Frequency 110/120 VAC - 50/60 Hz
Housing Code None
Seal Material Buna-N
Reducer Module No
AC/DC AC
Design No. 10
No. of Stages Two Stage
Pilot/Drain External Pilot/Internal Drain
Electrical Options Code None
Manual Override Plain Override
Spool Center Condition A Port and Double Offset sensing switch on B Port
Mounting Subplate/Manifold Mount
Body Material Gray Iron
Coil Type Code U
Mechanical Options None
Reducer Module Code None
Fluid Cleanliness 20/18/15 micron
Coil Rating Code B
Operation Pilot Operated
Rated Flow [Max] 175 gal/min
Pilot Drain Code None
Manual Override Option Code None
Leakage Standard Performance
Spool Indicator Switch Code None
Pressure Port Check Valve Pressure N/A
Valve Type Standard-Duty
Actuator Type Solenoid
Performance Standard Performance
Pilot Pressure Code None
Response Type Code None
Spool Spring Arrangement Code C
Solenoid Double
Solenoid Energization Code None
Weight 35.0 LB