- Solenoid Actuated Valve
- Pilot Operated Operation
- D08 NFPA Size
- Double Solenoid
- 3-Position Spring Centered Function
description
- DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.
caution
- Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
| Mechanical Options Code | None |
| Voltage & Frequency | 110/120 VAC - 50/60 Hz |
| Function | 3-Position Spring Centered |
| Body Material | Ductile Iron |
| Gauge Port Thread Type | 7/16 - 20 UNF, SAE Thread |
| NFPA Size | D08 |
| Pressure Port Check Valve Pressure | N/A |
| Response Type | Standard Response |
| Pilot Pressure Code | None |
| Pilot Drain Code | T |
| Port T Pressure Rating | 5000 psi |
| Solenoid Indicator Lights Code | L |
| Reducer Module Code | None |
| Pressure [Max] | 5000 psi |
| No. of Stages | Two Stage |
| Electrical Options Code | None |
| Mechanical Options | Adjust Pilot Chokes on Both Ends |
| Operation | Pilot Operated |
| Spool Code | 6 |
| Actuator Type | Solenoid |
| Surge Suppressor/Damper | None |
| Leakage | High Performance |
| AC/DC | AC |
| Rated Flow [Max] | 175 gal/min |
| Center Position | P Blocked, A & B to T |
| Coil Type | Flying Leads, 1/2 in NPT Thread Wiring Housing |
| Reducer Module | No |
| Coil Type Code | F |
| Electrical Connection | Wired Terminal Block |
| Overrides | Plain Override Solenoid Ends |
| Crossover | P Blocked, A or B to T |
| Electrical Connector Code | T |
| Pilot Valve Type | CETOP 3, High Performance |
| Seal Material | Buna-N |
| Tank Port Rating | 5000 |
| Solenoid | Double |
| Manual Override Option Code | None |
| Actuation Identification | Solenoid A, Solenoid B |
| Design No. | 10 |
| Temperature Range [Max] | 230 °F |
| Electrical Options | None |
| Spool Control Modification Code | 2 |
| Port Restrictor Plug Code | None |
| Spool Indicator Switch Code | None |
| Coil Rating Code | B |
| Solenoid Energization Code | None |
| Pilot Valve Type Code | H |
| Valve Type | Standard-Duty |
| Spool Spring Arrangement Code | C |
| Surge Suppressor/Damper Code | None |
| Port Restrictor Plugs | None |
| Manual Override | Plain Override |
| Mounting | Subplate/Manifold Mount |
| Pilot/Drain | External Pilot/Internal Drain |
| Compatible Fluids | Petroleum Oil |
| Response Type Code | None |
| Temperature Range [Min] | -40 °F |
| Housing Code | W |
| Fluid Cleanliness | 19/17/14 micron |
| Pressure Port Check Valve Code | None |
| Indicator Lights | Yes |
| Performance | High Performance |
| Gauge Port | SAE-4 |
| Model No. | DG5V-8-H-6C-2-T-M-FTWL-B-10 |
| EN Code | None |
| Gauge Ports Code | None |
| Weight | 35.0 LB |