Vickers by Danfoss02-342421

02-342421

Vickers D08 Solenoid Valve
Item #101919570
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function
Vickers by Danfoss02-342421
Price Unavailable
Price Unavailable
Pricing is unavailable at this time. Please contact Customer Service for assistance.
Online Ordering Restricted
Please contact Customer Service for assistance.
Contact Customer Service
    Shipment Options
  • Solenoid Actuated Valve
  • Pilot Operated Operation
  • D08 NFPA Size
  • Double Solenoid
  • 3-Position Spring Centered Function

description

  • DG5V-8 models are two-stage directional control valves having an integrally-mounted wet armature solenoid pilot valve. These valves are generally used to control the movement of a work cylinder or the rotation of a fluid motor.

caution

  • Any sliding spool valve, if held for long periods of time, may stick and not spring return due to fluid residue formation and therefore should be cycled periodically to prevent this from happening
Spool Control Modification Code None
Gauge Port SAE-4
Actuator Type Solenoid
Manual Override Plain Override
AC/DC AC
Fluid Cleanliness 19/17/14 micron
Performance High Performance
Mechanical Options Code None
Coil Type Flying Leads, 1/2 in NPT Thread Wiring Housing
Electrical Options Code None
Spool Indicator Switch Code None
Reducer Module No
Solenoid Energization Code None
Body Material Ductile Iron
Leakage High Performance
Spool Code 3
Valve Type Standard-Duty
Pressure [Max] 5000 psi
Spool Spring Arrangement Code C
Solenoid Double
Indicator Lights Yes
Surge Suppressor/Damper None
Gauge Port Thread Type 7/16 - 20 UNF, SAE Thread
Solenoid Indicator Lights Code L
Pilot Drain Code T
Seal Material Buna-N
Surge Suppressor/Damper Code None
Function 3-Position Spring Centered
Compatible Fluids Petroleum Oil
Coil Type Code F
Pilot/Drain Internal Pilot/Internal Drain
Pressure Port Check Valve Pressure 5 psi
No. of Stages Two Stage
Rated Flow [Max] 175 gal/min
Operation Pilot Operated
Center Position P & B Blocked, A to T
Gauge Ports Code None
Port Restrictor Plug Code None
Pilot Pressure Code None
Electrical Connector Code T
Crossover All Ports Blocked, or P & B Blocked, A to T
Electrical Connection Wired Terminal Block
Pilot Valve Type Code H
Port Restrictor Plugs None
Temperature Range [Min] -40 °F
Pressure Port Check Valve Code K
Response Type Code None
Model No. DG5V-8-H-3C-T-K-M-FTWL-B-10
Overrides Plain Override Solenoid Ends
Pilot Valve Type CETOP 3, High Performance
Housing Code W
Electrical Options None
Manual Override Option Code None
NFPA Size D08
Voltage & Frequency 110/120 VAC - 50/60 Hz
Tank Port Rating 5000
Mounting Subplate/Manifold Mount
Design No. 10
Coil Rating Code B
Response Type Standard Response
EN Code None
Reducer Module Code None
Port T Pressure Rating 5000 psi
Mechanical Options None
Actuation Identification Solenoid A, Solenoid B
Temperature Range [Max] 230 °F
Weight 35.0 LB